Häufig gestellte Fragen

Brauchen Sie technischen Support?

The CM4SL GUI cannot connect to Simulink

Frage

In the setup of a locally installed CarMaker and receiving a license via VPN connection from your company server, it might happen that the CM4SL GUI is not able to connect to Simulink when clicking the “Open GUI” block in Simulink and will show the error “No connection to CarMaker GUI”.

Antwort

If this is the case please use following workaround:

Before using the “Open GUI” block run the following command in the MATLAB Command Window:
CMData.GuiArgs={‘-apphost‘, ‘localhost‘}

This enables the connection between GUI and Simulink.

Brauchen Sie technischen Support?
  • Datum: 31.03.2020
  • Produkt: CarMaker
  • Version: 9.1
  • Komponente: CM4SL
  • Sprache: Englisch

Tags

VPN
CarMaker for Simulink
connection error